A pond’s surface acreage (S.A.) is determined by multiplying its length by its width. A pond’s actual shape and depth should all be considered when selecting horsepower and unit size.
HORSEPOWER
SUGGESTED
POND SIZE (S.A.)
MINIMUM
OPERATING DEPTH
1/2
1/2
2'
1
3/4
3'
2
1
3'
3
1-1.5
3'
3.5
1-1.5
3'
5
2-1.5
3'
7.5
3
4'
10
4
4'
60Hz
Horsepower
1/2
1
2
3 & 3.5
5
HT x DIA ft UPPER
---
4 x 10
6 x 11
8 x 12
10 x 12
HT x DIA ft LOWER
---
3 x 22
4 x 26
5 x 32
6 x 35
GPM
N/A
305
345
412
532
50Hz
Horsepower
1
2
3
5
HT x DIA ft UPPER
6 x 10
6.5 x 10
7 x 12
12 x 12
HT x DIA ft LOWER
2.5 x 25
3 x 30
3 x 30
5 x 44
HT x DIA m UPPER
1.83 x 3.05
1.98 x 3.05
2.13 x 3.66
3.66 x 3.66
HT x DIA m LOWER
0.76 x 7.62
0.91 x 9.14
0.91 x 9.14
1.52 x 13.41